Distribution and Storage

Solutions

Need help?

Our Client care managers are on available answer your questions representative or submit a business inquiry online.

Contact Us

Hydrogen Refilling Station
Hydrogen Refilling Station
Hydrogen Era provides scenario-based analysis service for various hydrogen refueling station application, which includes preliminary planning, budgetary proposal, comparative analysis of products selection.

Technical Specifications

Item
Value
Unit
Compressor Hydraulic Driven
Power
55
KW
Inlet pressure
14~16
Bar
Discharge pressure
500/950
Bar
Dispenser
Power
15
KW
Inlet pressure(H35)
≤500
Bar
Inlet pressure(H70)
≤950
Bar
Design pressure(H35)
482
Bar
Design pressure(H70)
950
Bar
Maximum Flow Rate
≤3.6
Kg/min
Measure accuracy
≤ ±1.5
%
Refueling protocol
Meet SAE J2601
Accumulator Type | 500/950 Bar
Design pressure
552/1030
Bar
Working pressure
500/950
Bar
Water volume
4.145/0.5
m3
Hydrogen storage capacity
~129.6/~24.2
Kg
hydrogen distribution & storage

Hydrogen Era offer several typical liquefaction plant mainly includes

Technical Specifications

Product Parameter
Working Pressure
Liquefaction Power Consumption
p-H2
Normal Storage Pressure
Plant Power
Plant Area
10TPD
2~2.6MPa
<13Kwh/Kg-LH2
>95%
<50KPA
6.8MW
27000 M2
20TPD
2~2.6MPa
<11Kwh/Kg-LH2
>95%
<50KPA
12.8MW
40000 M2
30TPD
2-5.1MPa
≤10Kwh/Kg-LH2
>95%
<50KPA
14.7MW
54000 M2